2012-06-12Replacement of HP-Bypass Valves, Avedøre power plant unit 1 (Avedøreværket)
Replacement of HP-Bypass Valves, Avedøre power plant unit 1.
— Design and manufacturing of 2 ea. Safety valves including control station, valves, measurements and all other needed accessories for regulation of the HP-Bypass system,
— Design data steam: Flow 1003 m3/h, Temperature 170 °C, Pressure 314 baro, Setting press safety valve 275 bar,
— Dimension of safety valves: Inlet (ODxID) 280 x 140 mm, Outlet (ODxID) Approx. 376 x 295 mm.
Se udbuddet »
2011-09-20Major overhaul of Avedøreværket(AVV) unit 1 steam turbine section MP2 and LP (Avedøreværket)
Major overhaul of AVV unit 1 steam turbine section MP2 and LP.
Unit 1 was commissioned in 1990 and is a 262 MW BBC turbine with a steam pressure of 240 bar and steam temperature of 540 C running at 3000 RPM. It consist of a high pressure section, two medium pressure sections and a low pressure section. The work concerns the second medium pressure (IP2) section and the low pressure section (LP), both of which are with dual outlet with asymmetrical outlet pressures. The condenser pressure after the …
Se udbuddet » Nævnte leverandører:Turbocare Sp.zo.o