DTU requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. See more in the document ‘Instructions to tenderers’.
Deadline
Fristen for modtagelse af bud var på 2020-08-05.
Indkøbet blev offentliggjort på 2020-06-26.
Leverandører
Følgende leverandører er nævnt i tildelingsbeslutninger eller andre indkøbsdokumenter:
Udbudsbekendtgørelse (2020-06-26) Objekt Omfanget af udbuddet
Titel: Massespektrometer
Kort beskrivelse:
DTU requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. See more in the document ‘Instructions to tenderers’.
DTU requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. See more in the document ‘Instructions to tenderers’.
Bekendtgørelsens metadata
Originalsprog: engelsk 🗣️
Dokumenttype: Udbudsbekendtgørelse
Kontraktens art: Varer
Forordning: Den Europæiske Union, med deltagelse af GPA-lande
Fælles glossar for offentlige kontrakter (CPV)
Kode: Massespektrometer📦
Yderligere CPV-kode: Apparater til fysisk eller kemisk analyse📦 Sted for udførelsen
NUTS-region: Hovedstaden
🏙️
Procedure
Procedureform: Offentligt udbud
Bud-type: Indsendelse gældende for alle delaftaler
Kriterier for tildeling
Det økonomisk mest fordelagtige bud
Objekt Omfanget af udbuddet
Anslået samlet værdi: 6 500 000 DKK 💰
Kort beskrivelse:
The DTU Department of Bioengineering requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. Required molecular feature information in data independent.
The DTU Department of Bioengineering requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. Required molecular feature information in data independent.
Acquisition includes collisional cross section (CCS) values for precursor ions, fragmentation spectra, and accurate mass of precursor and product ions.
The MS will become part of a metabolomics platform within the Bioengineering Department at the Technical University of Denmark, and therefore, the MS will have a wide variety of users, and data acquired from this MS will be used in teaching settings. To this effect, the required MS must be user friendly, and must be accompanied by a reasonable solution to providing multiple students, short term access to data analysis software.
The MS will become part of a metabolomics platform within the Bioengineering Department at the Technical University of Denmark, and therefore, the MS will have a wide variety of users, and data acquired from this MS will be used in teaching settings. To this effect, the required MS must be user friendly, and must be accompanied by a reasonable solution to providing multiple students, short term access to data analysis software.
Anslået værdi uden moms: 6 500 000 DKK 💰
Varighed: 60 måneder
Beskrivelse af mulighederne:
Service option 1: DTU would like an option of an extended service agreement. The tenderer should provide and option for a 1 year full service agreement.
Service option 2: DTU would like an option of an extended service agreement. The tenderer should provide and option for 4 years extended full service agreement.
Preventative maintenance option 1: DTU would like an option of a preventative maintenance agreement. The tenderer should provide an option for an additional 1 year of preventative maintenance services.
Preventative maintenance option 2: DTU would like an option of a preventative maintenance agreement. The tenderer should provide and option for an additional 4 years of preventative maintenance services.
Sted for udførelsen
Hovedsted eller sted for udførelsen: Kgs. Lyngby.
Juridiske, økonomiske, finansielle og tekniske oplysninger Betingelser for deltagelse
Mindstekrav til niveauet:
To be sure the tenderer possess the necessary level for economic and financial standing, it’s a requirement, that the tenderer by 1 June 2020 has a minimum equity of DKK 1 000 000.00.
If the tenderer can’t state the required figure for economic and financial standing, the tenderer can document their economic and financial standing by sending an on-demand guarantee with a value of DKK 1 000 000.00.
If the tenderer cannot comply with the requirement, the tenderer can rely on the capacities of other entities or establish a consortium.
To be sure the tenderer possess the necessary level of technical and professional ability, it’s a requirement, that the tenderer as a minimum give 3 references for comparable agreements.
Comparable agreements shall mean agreements with a value of at least DKK 2 000 000.00 regarding delivery of a mass spectrometer. The agreement the reference is referring to can’t be more than 3 year olds, counted from the date of delivery of the mass spectrometer.
Comparable agreements shall mean agreements with a value of at least DKK 2 000 000.00 regarding delivery of a mass spectrometer. The agreement the reference is referring to can’t be more than 3 year olds, counted from the date of delivery of the mass spectrometer.
If the tenderer is unable to fulfil the requirement, the tenderer can rely on the capacities of other entities or make a consortium.
Procedure
Retsgrundlag: 32014L0024
Tidspunkt for modtagelse af tilbud: 14:00
Sprog, på hvilke bud eller ansøgninger om deltagelse kan indgives: engelsk 🗣️
Tilbuddets gyldighedsperiode: 6 måneder
Dato for åbning af tilbud: 2020-08-05 📅
Tidspunkt for åbning af tilbud: 14:00
Kriterier for tildeling
Kvalitetskriterium (navn): Quality and functionality
Kvalitetskriterium (vægtning): 70 %
Pris (justeringskoefficient): 30 %
Supplerende oplysninger Gennemgå organ
Navn: Klagenævnet for Udbud
Postadresse: Nævnenes hus, Toldboden 2
Postby: Viborg
Postnummer: 8800
Land: Danmark 🇩🇰
Telefon: +45 35291000📞
E-mail: klfu@erst.dk📧
Internetadresse: http://www.klfu.dk🌏
Oplysninger om frister for klageprocedurer:
Complaint regarding the award of contract:
Complaint regarding the award of contract must be submitted no later than 45 calendar days from the date after the contracting authority has published a contract award notice in the European Union Official Journal informing that the contracting authority has awarded the contract, cf. lov om Klagenævnet for Udbud § 7, section 2, no 1.
Complaint regarding the award of contract must be submitted no later than 45 calendar days from the date after the contracting authority has published a contract award notice in the European Union Official Journal informing that the contracting authority has awarded the contract, cf. lov om Klagenævnet for Udbud § 7, section 2, no 1.
Tjeneste, hvorfra der kan indhentes oplysninger om klageproceduren
Navn: Konkurrence- og Forbrugerstyrelsen
Postadresse: Carl Jacobsens Vej 35
Postby: Valby
Postnummer: 2500
Telefon: +45 41715000📞
E-mail: kfst@kfst.dk📧
Internetadresse: http://www.kfst.dk🌏
Kilde: OJS 2020/S 124-303279 (2020-06-26)
Bekendtgørelse om indgåede kontrakter (2020-10-21) Objekt Omfanget af udbuddet
Kort beskrivelse:
DTU requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high-quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. See more in the document ‘Instructions to tenderers’.
DTU requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high-quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. See more in the document ‘Instructions to tenderers’.
Den samlede værdi af udbuddet: 7 213 275 DKK 💰
Bekendtgørelsens metadata
Dokumenttype: Bekendtgørelse om indgåede kontrakter
The DTU Department of Bioengineering requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high-quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. Required molecular feature information in data independent acquisition includes collisional cross section (CCS) values for precursor ions, fragmentation spectra, and accurate mass of precursor and product ions.
The DTU Department of Bioengineering requires a mass spectrometer (MS) with ion mobility and capable of mass spectrometry imaging (MSI), as well as electrospray ionisation (ESI). The MS that is required must be capable of acquiring MSI data at a very small spatial resolution as the primary application of the MS will be in the detection of secondary metabolites produced by microorganisms. The MS needs to have a relatively high mass resolution that is independent of acquisition rate, as the primary application for the MS will be in the detection of secondary metabolites in chemically complex samples with the purpose of undertaking non-targeted multivariate metabolomics studies. The predominant application of the MS will be in non-targeted metabolomics (either in MSI, or ESI), and therefore the required MS must produce high-quality data in data independent acquisition with high sensitivity, at the same time maximising molecular feature information quality. Required molecular feature information in data independent acquisition includes collisional cross section (CCS) values for precursor ions, fragmentation spectra, and accurate mass of precursor and product ions.
Beskrivelse af mulighederne:
Service option 1: DTU would like an option of an extended service agreement. The tenderer should provide and option for a 1-year full service agreement.
Tildeling af kontrakt
Dato for kontraktindgåelse: 2020-10-21 📅
Navn: Bruker Nordic AB
Nationalt registreringsnummer: Bruker Nordic
Postadresse: Vallgatan 5
Postby: Solna
Postnummer: 17067
Land: Sverige 🇸🇪
Telefon: +46 704741155📞
E-mail: patrik.ek@bruker.com📧
Den samlede værdi af udbuddet: 7 213 275 DKK 💰
Oplysninger om udbud
Antal modtagne bud: 2
Supplerende oplysninger Gennemgå organ
Oplysninger om frister for klageprocedurer:
Complaint regarding the award of contract must be submitted no later than 45 calendar days from the date after the contracting authority has published a contract award notice in the European Union Official Journal informing that the contracting authority has awarded the contract, cf. lov om Klagenævnet for Udbud § 7, section 2, No 1.
Complaint regarding the award of contract must be submitted no later than 45 calendar days from the date after the contracting authority has published a contract award notice in the European Union Official Journal informing that the contracting authority has awarded the contract, cf. lov om Klagenævnet for Udbud § 7, section 2, No 1.